| Brand | EATON |
|---|---|
| Manufacturer Part Number | XTPR040DC1 |
| Type | INDUSTRIAL CONTROL AUTOMATION MOTOR CONTROLS MANUAL MOTOR P |
| Features | MANUAL MOTOR PROTECTOR, NEMA SIZE NOT APPLICABLE, HORSEPOWER SINGLE PHASE 120V AC 3 HP, HORSEPOWER SINGLE PHASE 240V AC 7 1/2 HP, MAXIMUM VOLTAGE RATING 600V AC, NUMBER OF POLES 3, OPERATOR SELECTOR SWITCH, PHASE THREE, CURRENT AC 40 A, HORSEPOWER THREE PHASE 208V AC 10 HP, HORSEPOWER THREE PHASE 480V AC 30 HP, SERIES XTPR SERIES, HORSEPOWER THREE PHASE 600V AC 40 HP, MAXIMUM OVERLOAD RELAY CURRENT SETTING 40 A, MINIMUM OVERLOAD RELAY CURRENT SETTING 32 A |
| Item Height | 6.500 |
| Item Length | 5.800 |
| Item Width | 2.500 |
| Country/region Of Manufacture | DE |
| Custom Bundle | NO |
| Size | 55 MM |
| Weight | 2.6600 |
| UPC | 786685364339 |
The Eaton XTPR040DC1 Manual MTR Protector is a highly efficient and reliable circuit breaker designed for a wide range of industrial and commercial applications. This device is part of Eaton's XT Protection series, known for its advanced technology and robust design.
The MTR Protector is a 40A rotary frame type breaker, which means it features a rotating handle mechanism that makes it easy to operate. It's designed for use with single-phase, 2-wire systems, and is suitable for both indoor and outdoor applications.
The breaker is rated for a continuous current of 40 amperes, making it ideal for protecting low-power circuits. Its interrupting capacity, however, is much higher, at 30,000 amperes, which allows it to interrupt short-circuits and other faults that can cause significant current surges.
One of the key features of the Eaton XTPR040DC1 Manual MTR Protector is its thermal magnetic trip unit. This unit utilizes both thermal and magnetic trip elements, providing reliable protection against overloads and short circuits, respectively. The breaker also features a organizations such as UL, CSA, and CE, ensuring compliance with various international safety standards.
The design of the breaker is compact and rugged, making it well-suited for harsh environments. It's constructed from high-quality materials, including copper bus conductors and a unique vacuum interrupter system, to withstand the rigors of industrial use.
Maintaining the Eaton XTPR040DC1 Manual MTR Protector is a breeze, thanks to its front-access design. The breaker's components are easily accessible, allowing for quick and efficient maintenance. Additionally, a clear window in the breaker cover provides visibility of the tripping mechanism, making fault diagnosis simpler and more accurate.
Overall, the Eaton XTPR040DC1 Manual MTR Protector is an excellent choice for those in need of a dependable and versatile circuit breaker. With its advanced protection technology, rugged design, and ease of maintenance, it's sure to provide years of reliable service.
- High Current Capacity: The Eaton XTPR040DC1 Manual MTR Protector 40A Rotary Frame is designed to handle high current loads up to 40 Amperes, making it suitable for use in applications that require heavy current protection.
- Manual Reset: This device comes with a manual reset feature, which can be helpful in situations where automatic reset is not desirable or feasible. Manual reset allows for quick and easy restoration of power after a fault.
- Durable Construction: Eaton is a reputable brand known for producing high-quality electrical equipment. The Eaton XTPR040DC1 features robust and rugged construction, ensuring a long lifespan and reliability.
- Universal Application: This device can be used in a wide range of applications, including industrial, commercial, and residential settings, offering flexibility for potential buyers.
2. Cons:- Manual Reset: While having a manual reset feature can be advantageous, it may also lead to potential issues. Manual reset requires physical interaction to reset the device after a fault, which could lead to potential delays in system recovery particularly in mission-critical applications.
- Potential for User Error: The manual reset feature makes the Eaton XTPR040DC1 more prone to user error since it relies solely on the user to perform the reset function correctly. Improper resetting could cause further damage or even put personnel at risk.
- Comparatively Higher Cost: Compared to automatic reset circuit breakers, the Eaton XTPR040DC1 may cost more due to its manual reset feature and higher current capacity.
3. Conclusion:The Eaton XTPR040DC1 Manual MTR Protector 40A Rotary Frame is a suitable option for applications that require a high current capacity and the flexibility of manual reset. However, it may not be the most cost-effective choice and is more prone to potential user error compared to automatic reset options. Ultimately, the decision to purchase the Eaton XTPR040DC1 should depend on the specific needs of your application and your risk tolerance towards manual reset and potential user error.
4. Recommendation:For general-purpose applications with medium to high current requirements where automatic reset is preferred and cost is a concern, an automatic rest circuit breaker, such as the Eaton BRW series, might be a more suitable alternative. However, for specific applications calling for manual reset and high current capacity, the Eaton XTPR040DC1 Manual MTR Protector 40A Rotary Frame remains a viable option. Always consult with an electrical engineer or professional to determine the most appropriate equipment for your specific application.
Eaton XTPR040DC1 manual mtr protector,40a,rotary,frame d: motor protector, nema size not applicable, horsepower single phase - 120v ac 3 hp, 240v 7 1/2 maximum voltage rating 600v ac, number of poles 3, operator selector switch, three, current 40 a, three 208v 10 480v 30 series xtpr series, overload relay setting minimum 32 a details. Electrical outlet's. Light industrial. Receptacles.
And enclosures. Electrical boxes.